Chemistry
Chemistry and laboratory equipment
100ml glass spirit lamp with a screw-on aluminum base cap.
For measuring the strength of pure alcohol. Built-in thermometer with compensation scale. In plastic case. 0-100 Vol %, length 320 mm, 40 g
The model consists of:
a white top section with 4 black electron orbits;
a black bottom section with 4 white electron orbits;
30 protons, 30 neurons, 30 electrons
Topics covered:
atoms
isotopes
ions
noble gas configurations
element bonding
covalent bonds
ionic compounds
elements
atomic mass
atomic number
periodic table
The brush part measures 42 x 20 mm, total length 440 mm. The brush part is freely movable within a range of 100 degrees.
Go Direct® Constant Current System
The Go Direct Constant Current System is a DC power source with a built-in current probe designed for use in electrochemistry experiments. It connects via Bluetooth® wireless technology or via USB to your device.
Use the Go Direct Constant Current System to determine Avogadro’s number and perform various electroplating and electrolysis experiments. This system combines a DC power source with a built-in current sensor to eliminate the need for a separate power supply, and it can deliver up to 0.6 A at 5 V DC. Voltage settings are automatically adjusted to complement the chosen current setting.
Wireless or Wired—The Flexibility to Choose
Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our Vernier Graphical Analysis® app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the best solution for your classroom or laboratory.
Interested in doing more advanced electrochemistry experiments? Check out our Go Direct Cyclic Voltammetry System.
Specifications
- Range: 0 to 0.6 A
- Supply voltage: 5 VDC
- Connections:
- Wireless: Bluetooth
- Wired: USB
Give your students hands-on experience with electrochemical reactions using this affordable potentiostat and disposable screen-printed electrodes. The Go Direct Cyclic Voltammetry System is simple to use, includes free experiments in a downloadable e-book, and is supported by the free Vernier Instrumental Analysis® app.
With the Go Direct Cyclic Voltammetry System, developed in part with Pine Research (specialists in electrochemical research instrumentation), students can easily control and apply potential to a chemical system and measure the response as electrical current. Students can apply analytical techniques, such as cyclic voltammetry or bulk electrolysis, to determine the acetaminophen concentration in medication, to explore antioxidants in everyday beverages, to investigate Faraday’s law, and to understand cyclic voltammetry. Easily incorporate electrochemistry into your curriculum using our e-book Electrochemistry Experiments with the Go Direct Cyclic Voltammetry System available for free with your purchase.
Rechargeable Battery—Ready When You Are
The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.
Wired or Wireless—The Flexibility to Choose
Go Direct Cyclic Voltammetry System connects directly to your mobile device, Chromebook™, or computer using our free Vernier Instrumental Analysis® app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the solution best for your laboratory.
Specifications
Data Collection Modes
- Cyclic Voltammetry
- Bulk Electrolysis
- Open Circuit Potential
Potential Range
Operational range: –2000 to +2000 mV
Practical range*: –1200 to +1200 mV
*This range limit applies when using Vernier screen-printed electrodes in aqueous solutions. Results may vary when using other electrodes and solvents.
Current Ranges
- High (± 1000 μA)
- Medium (± 100 μA)
- Low (± 10 μA)
- Lowest (± 1 μA)
Dimensions
9 cm x 6 cm x 3 cm
Power
Internal rechargeable battery or USB connection
Connections
- Wireless: Bluetooth® wireless technology
- Wired: USB
| Delivery contents | Penetration probe thermometer, battery, instruction manual |
| Measuring range temperature | -40...+200°C (-40...+392°F) |
| Material | Plastic |
| Power consumption | Batteries |
| Batteries included | yes |
| Batteries | 1 x LR44 1.5 V |
| Dimensions | (L) 20 x (B) 16 x (H) 205 mm |
| Weight | 29 g |
Dimensions 630 x 550 mm. Metal
Drying rack with 60 bars and 6 hangers. Made of plastic-coated steel wire. For drying bottles, flasks, beakers, test tubes, and other laboratory glassware. Complete with drip tray. Dimensions 53 x 57 x 16 cm (W x H x D)
Small laboratory stove with power regulator. Heating plate d=80mm, base d=140mm, h=65mm. Power supply 230V, power 500W.
Single-zone tabletop stove
• Power: approx. 1500 W
• Hob: approx. 18.5 cm Ø
• Smooth temperature control
• Indicator light
• Dimensions: (W) 25 x (D) 29 x (H) 8.5 cm
Power supply 230V
Max weighing object 200g with a reading of 0.01g. Weighing plate d=105mm.
Battery power 9V (included) or external 230V adapter purchased separately for 20 EUR.
Filtering time according to Herzberg 10 sec.
Porosity 20-25 micrometers
Other sizes also available.
Filtering time according to Herzberg 180 sec.
Porosity 2-3 micrometers
Other sizes also available.
Filtering time according to Herzberg 20 sec.
Porosity 15 micrometers
Other sizes also available.
| Speed control range | 0-3000 RPM |
|---|---|
| Max. stirring volume (water) | 5 litres |
| Max. length of magnetic stirring element (bar) | 50 mm |
| Stirring liquid viscosity | up to 1170 mPa.s |
| Maximum continuous operation time | 24 hrs |
| Operation in closed laboratory rooms | at ambient temperature from +4°C to +40°C |
| Working plate size | 110×110 mm |
| Working surface material | Stainless steel |
| Overall dimensions (W×D×H) | 120×150×65 mm |
| Weight | 0.8 kg |
| Input current/power consumption | 12 V, 220 mA / 2.6 W |
| External power supply | Input AC 100–240 V; 50/60 Hz; Output DC 12 V |
For the quantitative determination of gas quantities during the electrolysis of water. Improved version with Schellbach measuring tubes for easier reading, as well as GL 18 threads for holding the coal electrodes. Level vessel is connected via a hose line.
Protection up to +250°C according to EN 407. Also protects against cold, cuts. Breathable, lined. Length: 400 mm, size: 11.
High quality red light diode laser pointer.
Powered by 2xAAA batteries.
dimensions: 138 x 18mm
weight: 24g
Suitable for determining solutions in chemistry. Turns red when the pH is below 4 and blue when the pH is above 9. 4.8 m in a roll.
| Speed control range | 250-1250 RPM |
|---|---|
| Max. stirring volume (water) | 15 litres |
| Plate temperature regulation range | +30°C...+330°C |
| Temperature uniformity on the plate | ±3°C |
| Working plate heating time till 330°C | 15 min |
| Maximum continuous operation time | 168 h |
| Diameter of working plate | 160 mm |
| Working surface material | Aluminium alloy |
| SR-1, attachable stand size | Ø 8 × 320 mm |
| Length of magnetic stirring element | 10–50 mm |
| Max. stirring liquid viscosity | up to 1170 mPa.s |
| Fault indication | Outputs sound signal and turns off the heating |
| Overall dimensions (W×D×H) | 190x270x100 mm |
| Weight | 2.9 kg |
| Power consumption (Stirring) | 8.5 W |
| Power consumption (Heating) | 550 W |
| Nominal operating voltage | 230 V; 50/60 Hz or 120 V; 50/60 Hz |
The Go Direct Melt Station accurately determines the melting temperature of solid substances. It connects via Bluetooth® wireless technology or via USB to your device.
Teach students the visual detection capillary method of melting point determination with the Go Direct Melt Station. It accurately measures melting temperatures of a solid (up to 260°C), and the real-time graphing provides a unique perspective of the melting process.
The wide-angle observation and magnification window, LED-lit heater block, and adjustable tilt base give students a clear view of the substance as they witness the state change. Internal cooling fans reduce the waiting time between sample testing. Also included is an important safety feature that automatically powers down the heating block after 60 minutes with no change to the control knob.
The Go Direct Melt Station can be used in a variety of experiments:
- Determine the melting temperature of an known organic solid such as aspirin, ibuprofen, or caffeine.
- Identify an unknown organic solid by its melting temperature.
- Use melting temperature to analyze reaction products.
Wireless or Wired—The Flexibility to Choose
Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our Vernier Graphical Analysis® app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the best solution for your classroom or laboratory.
Specifications
- Dimensions:
- Base: 13 cm × 15 cm × 1.5 cm
- Body: 9 cm × 9 cm × 24 cm
- Weight: 1.0 kg (2.2 lbs)
- Range: Ambient to 260°C
- Resolution: 0.10°C
- Accuracy: ±0.31 + 0.0006T, where T is the temperature in Celsius
- Safety shut down: The heating block is automatically powered down after approximately 60 minutes of heating.
- Capillary tubes: 1.4–1.8 mm outside diameter, 100 mm length
- Capillary tube slots: 3
- Viewing lens: 27 mm diameter (functional), 30 mm (actual)
- Lighting of capillary slots: 3 white LEDs
- Lighting of control dial:
- Red LED (indicates heating mode)
- Blue LED (indicates cooling mode with cooling fan running)
- Yellow LED (safety shut off activated)
- Connections:
- Wireless: Bluetooth
- Wired: USB
Description
Minicentrifuge-vortex Microspin FV-2400 is specially designed for genetic engineering research (for PCR–diagnostics experiments). Units can be used in microbiological, biochemical, clinical laboratories and industrial biotechnological laboratories.
Micro–Spin provides simultaneous mixing and separation of samples, using centrifuge and mixing modules, located on the common spin–module.
FV-2400 is an “open type” centrifuge (without lid), that increases the speed of centrifugation and resuspension operations.
| Rotation speed (fixed) (50 Hz) | 2800 rpm |
|---|---|
| Max. RCF (50 Hz) | 500 x g |
| Continuous and impulse operation modes | yes |
| Overall dimensions (W×D×H) | 120x170x120 mm |
| Weight | 1.4 kg |
| Power consumption (230V) | 25 W (0.1 A) |
| Nominal operating voltage | 230 V; 50 Hz |
Minicentrifuge-vortex Combi–Spin FVL-2400N is specially designed for genetic engineering research (for PCR–diagnostics experiments). Units can be used in microbiological, biochemical, clinical laboratories and industrial biotechnological laboratories.
Combi–Spin provides simultaneous mixing and separation of samples, using centrifuge and mixing modules, located on the common spin–module.
FVL-2400N is provided with protection mechanism that stops the rotor motion when the lid is opened.
| Rotation speed (fixed) (50 Hz) | 2800 rpm |
|---|---|
| Max. RCF (50 Hz) | 500 x g |
| Continuous and impulse operation modes | |
| Safety | Stop at open lid |
| Overall dimensions (W×D×H) | 190x235x125 mm |
| Weight | 1.7 kg |
| Power consumption (230V) | 25 W (0.1 A) |
| Nominal operating voltage | 230 V; 50 Hz |
pH buffer solutions 4.01; 7.00 and 10.00. Ready to use, in sachets, 25ml each.
Step 1.0 pH units, 100 strips
Min unit 1 pH unit. Roll 4.8m
For determination of bases, turns pink when pH is above 9. Roll 4.8 m.
The concept of chirality can be difficult for students to visualize. Go Direct Polarimeter provides a visual representation of this concept by measuring the optical rotation of optical isomers such as sugars, amino acids, and proteins. The Go Direct Polarimeter is simple to use, includes free, downloadable experiments, and is supported by the free Vernier Instrumental Analysis® app.
Its unique vertical layout and lack of custom glassware make this polarimeter very student friendly. In addition, the analyzer is automatically rotated by an internal motor giving students more time to understand experiments such as the reaction kinetics of HCl and sucrose. The 589 nm LED makes it ideal for comparing optical rotation values to those in literature, allowing students to calculate specific rotation for sucrose, fructose, and other optically active samples. Students no longer have to determine the optical maximum with their eye—they now have a graph that shows a clear change in the light’s polarization.
Rechargeable Battery—Ready When You Are
The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.
Wired or Wireless—The Flexibility to Choose
Go Direct Polarimeter connects directly to your mobile device, Chromebook™, or computer using our free Vernier Instrumental Analysis® app—no additional equipment or software purchases are necessary. Go Direct sensors connect via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the best solution for your laboratory.
Specifications
- Light source: LED
- Wavelength (nominal): 589 nm
- Accuracy (optical rotation measurements): ±1°
Al, Zn, Pb, Cu, Brass, Fe. Dimensions 75x24x3mm, equipped with screw terminals.
Diameter 10mm. Test tube cleaning brush, wool tip.
Collect temperature data directly through the USB port of a computer or Chromebook.
Specifications
- Range: -20°C – 115°C
- Maximum temperature that the sensor can tolerate without damage: 150°C
- Resolution: 0.07°C
- Accuracy: ± 0.5°C
- Response Time: 4s (to 90% of full reading in water)
UV lamp with handle.
2 wavelengths switchable: 254 nm and 366 nm.
Nominal lighting power: 6W
Power supply: 230V
Dimensions: 290 x 70 x 60 mm
Filter: 22*70mm
Water bath 2 liters for keeping the contents of test tubes and flasks, etc. at a constant temperature.
Internal dimensions of the bath l x w x h in the middle 135 x 125 x 145 mm. Volume approx. 2 L.
With thermostat. Power 200W, power supply 230V, temperature adjustable +5...+99 degrees, accuracy +-0.5 degrees.
Timer 1-999 minutes.
Protection against too low water level.
For measuring the strength of pure alcohol. Built-in thermometer with compensation scale. In plastic case. 0-100 Vol %, length 320 mm, 40 g
The model consists of:
a white top section with 4 black electron orbits;
a black bottom section with 4 white electron orbits;
30 protons, 30 neurons, 30 electrons
Topics covered:
atoms
isotopes
ions
noble gas configurations
element bonding
covalent bonds
ionic compounds
elements
atomic mass
atomic number
periodic table
The brush part measures 42 x 20 mm, total length 440 mm. The brush part is freely movable within a range of 100 degrees.
Go Direct® Constant Current System
The Go Direct Constant Current System is a DC power source with a built-in current probe designed for use in electrochemistry experiments. It connects via Bluetooth® wireless technology or via USB to your device.
Use the Go Direct Constant Current System to determine Avogadro’s number and perform various electroplating and electrolysis experiments. This system combines a DC power source with a built-in current sensor to eliminate the need for a separate power supply, and it can deliver up to 0.6 A at 5 V DC. Voltage settings are automatically adjusted to complement the chosen current setting.
Wireless or Wired—The Flexibility to Choose
Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our Vernier Graphical Analysis® app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the best solution for your classroom or laboratory.
Interested in doing more advanced electrochemistry experiments? Check out our Go Direct Cyclic Voltammetry System.
Specifications
- Range: 0 to 0.6 A
- Supply voltage: 5 VDC
- Connections:
- Wireless: Bluetooth
- Wired: USB
Give your students hands-on experience with electrochemical reactions using this affordable potentiostat and disposable screen-printed electrodes. The Go Direct Cyclic Voltammetry System is simple to use, includes free experiments in a downloadable e-book, and is supported by the free Vernier Instrumental Analysis® app.
With the Go Direct Cyclic Voltammetry System, developed in part with Pine Research (specialists in electrochemical research instrumentation), students can easily control and apply potential to a chemical system and measure the response as electrical current. Students can apply analytical techniques, such as cyclic voltammetry or bulk electrolysis, to determine the acetaminophen concentration in medication, to explore antioxidants in everyday beverages, to investigate Faraday’s law, and to understand cyclic voltammetry. Easily incorporate electrochemistry into your curriculum using our e-book Electrochemistry Experiments with the Go Direct Cyclic Voltammetry System available for free with your purchase.
Rechargeable Battery—Ready When You Are
The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.
Wired or Wireless—The Flexibility to Choose
Go Direct Cyclic Voltammetry System connects directly to your mobile device, Chromebook™, or computer using our free Vernier Instrumental Analysis® app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the solution best for your laboratory.
Specifications
Data Collection Modes
- Cyclic Voltammetry
- Bulk Electrolysis
- Open Circuit Potential
Potential Range
Operational range: –2000 to +2000 mV
Practical range*: –1200 to +1200 mV
*This range limit applies when using Vernier screen-printed electrodes in aqueous solutions. Results may vary when using other electrodes and solvents.
Current Ranges
- High (± 1000 μA)
- Medium (± 100 μA)
- Low (± 10 μA)
- Lowest (± 1 μA)
Dimensions
9 cm x 6 cm x 3 cm
Power
Internal rechargeable battery or USB connection
Connections
- Wireless: Bluetooth® wireless technology
- Wired: USB
| Delivery contents | Penetration probe thermometer, battery, instruction manual |
| Measuring range temperature | -40...+200°C (-40...+392°F) |
| Material | Plastic |
| Power consumption | Batteries |
| Batteries included | yes |
| Batteries | 1 x LR44 1.5 V |
| Dimensions | (L) 20 x (B) 16 x (H) 205 mm |
| Weight | 29 g |
Drying rack with 60 bars and 6 hangers. Made of plastic-coated steel wire. For drying bottles, flasks, beakers, test tubes, and other laboratory glassware. Complete with drip tray. Dimensions 53 x 57 x 16 cm (W x H x D)
Small laboratory stove with power regulator. Heating plate d=80mm, base d=140mm, h=65mm. Power supply 230V, power 500W.
Single-zone tabletop stove
• Power: approx. 1500 W
• Hob: approx. 18.5 cm Ø
• Smooth temperature control
• Indicator light
• Dimensions: (W) 25 x (D) 29 x (H) 8.5 cm
Power supply 230V
Max weighing object 200g with a reading of 0.01g. Weighing plate d=105mm.
Battery power 9V (included) or external 230V adapter purchased separately for 20 EUR.
Filtering time according to Herzberg 10 sec.
Porosity 20-25 micrometers
Other sizes also available.
Filtering time according to Herzberg 180 sec.
Porosity 2-3 micrometers
Other sizes also available.
Filtering time according to Herzberg 20 sec.
Porosity 15 micrometers
Other sizes also available.
| Speed control range | 0-3000 RPM |
|---|---|
| Max. stirring volume (water) | 5 litres |
| Max. length of magnetic stirring element (bar) | 50 mm |
| Stirring liquid viscosity | up to 1170 mPa.s |
| Maximum continuous operation time | 24 hrs |
| Operation in closed laboratory rooms | at ambient temperature from +4°C to +40°C |
| Working plate size | 110×110 mm |
| Working surface material | Stainless steel |
| Overall dimensions (W×D×H) | 120×150×65 mm |
| Weight | 0.8 kg |
| Input current/power consumption | 12 V, 220 mA / 2.6 W |
| External power supply | Input AC 100–240 V; 50/60 Hz; Output DC 12 V |
For the quantitative determination of gas quantities during the electrolysis of water. Improved version with Schellbach measuring tubes for easier reading, as well as GL 18 threads for holding the coal electrodes. Level vessel is connected via a hose line.
Protection up to +250°C according to EN 407. Also protects against cold, cuts. Breathable, lined. Length: 400 mm, size: 11.
High quality red light diode laser pointer.
Powered by 2xAAA batteries.
dimensions: 138 x 18mm
weight: 24g
Suitable for determining solutions in chemistry. Turns red when the pH is below 4 and blue when the pH is above 9. 4.8 m in a roll.
| Speed control range | 250-1250 RPM |
|---|---|
| Max. stirring volume (water) | 15 litres |
| Plate temperature regulation range | +30°C...+330°C |
| Temperature uniformity on the plate | ±3°C |
| Working plate heating time till 330°C | 15 min |
| Maximum continuous operation time | 168 h |
| Diameter of working plate | 160 mm |
| Working surface material | Aluminium alloy |
| SR-1, attachable stand size | Ø 8 × 320 mm |
| Length of magnetic stirring element | 10–50 mm |
| Max. stirring liquid viscosity | up to 1170 mPa.s |
| Fault indication | Outputs sound signal and turns off the heating |
| Overall dimensions (W×D×H) | 190x270x100 mm |
| Weight | 2.9 kg |
| Power consumption (Stirring) | 8.5 W |
| Power consumption (Heating) | 550 W |
| Nominal operating voltage | 230 V; 50/60 Hz or 120 V; 50/60 Hz |
The Go Direct Melt Station accurately determines the melting temperature of solid substances. It connects via Bluetooth® wireless technology or via USB to your device.
Teach students the visual detection capillary method of melting point determination with the Go Direct Melt Station. It accurately measures melting temperatures of a solid (up to 260°C), and the real-time graphing provides a unique perspective of the melting process.
The wide-angle observation and magnification window, LED-lit heater block, and adjustable tilt base give students a clear view of the substance as they witness the state change. Internal cooling fans reduce the waiting time between sample testing. Also included is an important safety feature that automatically powers down the heating block after 60 minutes with no change to the control knob.
The Go Direct Melt Station can be used in a variety of experiments:
- Determine the melting temperature of an known organic solid such as aspirin, ibuprofen, or caffeine.
- Identify an unknown organic solid by its melting temperature.
- Use melting temperature to analyze reaction products.
Wireless or Wired—The Flexibility to Choose
Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our Vernier Graphical Analysis® app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the best solution for your classroom or laboratory.
Specifications
- Dimensions:
- Base: 13 cm × 15 cm × 1.5 cm
- Body: 9 cm × 9 cm × 24 cm
- Weight: 1.0 kg (2.2 lbs)
- Range: Ambient to 260°C
- Resolution: 0.10°C
- Accuracy: ±0.31 + 0.0006T, where T is the temperature in Celsius
- Safety shut down: The heating block is automatically powered down after approximately 60 minutes of heating.
- Capillary tubes: 1.4–1.8 mm outside diameter, 100 mm length
- Capillary tube slots: 3
- Viewing lens: 27 mm diameter (functional), 30 mm (actual)
- Lighting of capillary slots: 3 white LEDs
- Lighting of control dial:
- Red LED (indicates heating mode)
- Blue LED (indicates cooling mode with cooling fan running)
- Yellow LED (safety shut off activated)
- Connections:
- Wireless: Bluetooth
- Wired: USB
Description
Minicentrifuge-vortex Microspin FV-2400 is specially designed for genetic engineering research (for PCR–diagnostics experiments). Units can be used in microbiological, biochemical, clinical laboratories and industrial biotechnological laboratories.
Micro–Spin provides simultaneous mixing and separation of samples, using centrifuge and mixing modules, located on the common spin–module.
FV-2400 is an “open type” centrifuge (without lid), that increases the speed of centrifugation and resuspension operations.
| Rotation speed (fixed) (50 Hz) | 2800 rpm |
|---|---|
| Max. RCF (50 Hz) | 500 x g |
| Continuous and impulse operation modes | yes |
| Overall dimensions (W×D×H) | 120x170x120 mm |
| Weight | 1.4 kg |
| Power consumption (230V) | 25 W (0.1 A) |
| Nominal operating voltage | 230 V; 50 Hz |
Minicentrifuge-vortex Combi–Spin FVL-2400N is specially designed for genetic engineering research (for PCR–diagnostics experiments). Units can be used in microbiological, biochemical, clinical laboratories and industrial biotechnological laboratories.
Combi–Spin provides simultaneous mixing and separation of samples, using centrifuge and mixing modules, located on the common spin–module.
FVL-2400N is provided with protection mechanism that stops the rotor motion when the lid is opened.
| Rotation speed (fixed) (50 Hz) | 2800 rpm |
|---|---|
| Max. RCF (50 Hz) | 500 x g |
| Continuous and impulse operation modes | |
| Safety | Stop at open lid |
| Overall dimensions (W×D×H) | 190x235x125 mm |
| Weight | 1.7 kg |
| Power consumption (230V) | 25 W (0.1 A) |
| Nominal operating voltage | 230 V; 50 Hz |
pH buffer solutions 4.01; 7.00 and 10.00. Ready to use, in sachets, 25ml each.
The concept of chirality can be difficult for students to visualize. Go Direct Polarimeter provides a visual representation of this concept by measuring the optical rotation of optical isomers such as sugars, amino acids, and proteins. The Go Direct Polarimeter is simple to use, includes free, downloadable experiments, and is supported by the free Vernier Instrumental Analysis® app.
Its unique vertical layout and lack of custom glassware make this polarimeter very student friendly. In addition, the analyzer is automatically rotated by an internal motor giving students more time to understand experiments such as the reaction kinetics of HCl and sucrose. The 589 nm LED makes it ideal for comparing optical rotation values to those in literature, allowing students to calculate specific rotation for sucrose, fructose, and other optically active samples. Students no longer have to determine the optical maximum with their eye—they now have a graph that shows a clear change in the light’s polarization.
Rechargeable Battery—Ready When You Are
The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.
Wired or Wireless—The Flexibility to Choose
Go Direct Polarimeter connects directly to your mobile device, Chromebook™, or computer using our free Vernier Instrumental Analysis® app—no additional equipment or software purchases are necessary. Go Direct sensors connect via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the best solution for your laboratory.
Specifications
- Light source: LED
- Wavelength (nominal): 589 nm
- Accuracy (optical rotation measurements): ±1°
Al, Zn, Pb, Cu, Brass, Fe. Dimensions 75x24x3mm, equipped with screw terminals.
Collect temperature data directly through the USB port of a computer or Chromebook.
Specifications
- Range: -20°C – 115°C
- Maximum temperature that the sensor can tolerate without damage: 150°C
- Resolution: 0.07°C
- Accuracy: ± 0.5°C
- Response Time: 4s (to 90% of full reading in water)
UV lamp with handle.
2 wavelengths switchable: 254 nm and 366 nm.
Nominal lighting power: 6W
Power supply: 230V
Dimensions: 290 x 70 x 60 mm
Filter: 22*70mm
Water bath 2 liters for keeping the contents of test tubes and flasks, etc. at a constant temperature.
Internal dimensions of the bath l x w x h in the middle 135 x 125 x 145 mm. Volume approx. 2 L.
With thermostat. Power 200W, power supply 230V, temperature adjustable +5...+99 degrees, accuracy +-0.5 degrees.
Timer 1-999 minutes.
Protection against too low water level.